{"excitationOptics":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","source":"Source","wavelength-range":"Gamme de longueurs d'onde","calcium-and-potassium":"Calcium et potassium","membrane-potential":"Potentiel membranaire","fura-2-a":"Fura-2 a","fura-2-b":"Fura-2 b","voltage-sensor-probes":"Sondes VSP (Votalge Sensor Probes)","mqae":"MQAE","cfp":"CFP","alexa-633-bodipy":"Alexa 633 et Bodipy"},{"key":"value1","name":"Optiques d'excitation","path":"\/products\/flipr-penta-high-throughput-cellular-screening-system","identifier":"FLIPR Penta High-Throughput Cellular Screening System","source":"Diodes électroluminescentes (LED) ou aucune source","wavelength-range":"335 à 626 nm","calcium-and-potassium":"470 à 495 nm","membrane-potential":"510 à 545 nm","fura-2-a":"335 à 345 nm","fura-2-b":"380 à 390 nm","voltage-sensor-probes":"390 à 420 nm","mqae":"360 à 380 nm","cfp":"420 à 455 nm","alexa-633-bodipy":"610 à 626 nm"}],"columns":["key","name","path","identifier","source","wavelength-range","calcium-and-potassium","membrane-potential","fura-2-a","fura-2-b","voltage-sensor-probes","mqae","cfp","alexa-633-bodipy"]},"general":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","dimensions-in":"Dimensions (pouces)","dimensions-cm":"Dimensions (cm)","weight-approx":"Poids (approx.)"},{"key":"value1","name":"Caractéristiques générales","path":"\/products\/flipr-penta-high-throughput-cellular-screening-system","identifier":"FLIPR Penta High-Throughput Cellular Screening System","dimensions-in":"39 (L) x 70 (H) x 27 (P)","dimensions-cm":"99 (L) x 178 (H) x 69 (P)","weight-approx":"386 kg (850 lb)"}],"columns":["key","name","path","identifier","dimensions-in","dimensions-cm","weight-approx"]},"emissionFilters":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","3-position-filter-slider":"Lame de filtre 3 positions","source":"Source","wavelength-range":"Gamme de longueurs d'onde","calcium-and-potassium":"Calcium et potassium","membrane-potential":"Potentiel membranaire","fura-2-a":"Fura-2 a","fura-2-b":"Fura-2 b","voltage-sensor-probes":"Sondes VSP (Votalge Sensor Probes)","cfp":"CFP","alexa-633-bodipy":"Alexa 633 et Bodipy"},{"key":"value1","name":"Filtres d'émission","path":"\/products\/flipr-penta-high-throughput-cellular-screening-system","identifier":"FLIPR Penta High-Throughput Cellular Screening System","3-position-filter-slider":"ID longueur d’ondedu filtre","source":"Diodes électroluminescentes (LED) ou aucune source","wavelength-range":"400 à 750 nm","calcium-and-potassium":"515 à 575 nm","membrane-potential":"565 à 625 nm","fura-2-a":"475 à 535 nm","fura-2-b":"475 à 535 nm","voltage-sensor-probes":"440 à 480 nm 565 à 625 nm","cfp":"475 à 535 nm","alexa-633-bodipy":"646 à 706 nm"}],"columns":["key","name","path","identifier","3-position-filter-slider","source","wavelength-range","calcium-and-potassium","membrane-potential","fura-2-a","fura-2-b","voltage-sensor-probes","cfp","alexa-633-bodipy"]},"emissionOptics-2":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","camera-type":"Type d'appareil photographique","detection":"Détection","lower-detection-limit-fluorescence":"Limite de détection inférieure (Fluorescence)","lower-detection-limit-luminescence":"Limite de détection inférieure (Luminescence)","data-acquisition-rate-fluorescence":"Vitesse d’acquisition des données (Fluorescence)","data-acquisition-rate-luminescence":"Vitesse d’acquisition des données (Luminescence)"},{"key":"value1","name":"Optiques d’émission - 2","path":"\/products\/flipr-penta-high-throughput-cellular-screening-system","identifier":"FLIPR Penta High-Throughput Cellular Screening System","camera-type":"EMCCD","detection":"Fluorescence","lower-detection-limit-fluorescence":"1,25 nm FITC","lower-detection-limit-luminescence":"-","data-acquisition-rate-fluorescence":"7 Hz","data-acquisition-rate-luminescence":"7 Hz"}],"columns":["key","name","path","identifier","camera-type","detection","lower-detection-limit-fluorescence","lower-detection-limit-luminescence","data-acquisition-rate-fluorescence","data-acquisition-rate-luminescence"]},"fluidics":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","simultaneous-transfer":"Transfert simultané","range-96-pipettor-head":"Gamme  : tête de pipetage 96","precision-@75-μl":"Précision à 75 μl","pipetting-increments-96-pipettor-head":"Incréments de pipetage - tête de pipetage 96 puits","range---384-well-pipettor":"Gamme – pipeteur à 384 puits","precision-@-25-μl":"Précision à 25 μl","pipetting-increments---384-well-pipettor":"Incréments de pipetage – pipeteur à 384 puits","range---1536-well-pipettor":"Gamme – pipeteur à 1536 puits","precision-@-3-μl":"Précision à 3 μl","precision-@-1-μl":"Précision à 1 μl","pipetting-increments---1536-well-pipettor":"Incréments de pipetage – pipeteur à 1536 puits","96-pipettor-head---quadrant-transfer":"Tête de pipetage 96 - Transfert de quadrant","384-pipettor-head---quadrant-transfer":"Tête de pipetage 384 - Transfert de quadrant"},{"key":"value1","name":"Système fluidique","path":"\/products\/flipr-penta-high-throughput-cellular-screening-system","identifier":"FLIPR Penta High-Throughput Cellular Screening System","simultaneous-transfer":"96, 384 et 1536","range-96-pipettor-head":"5 à 200 μL","precision-@75-μl":"3 % CV","pipetting-increments-96-pipettor-head":"1 μL","range---384-well-pipettor":"1 à 25 μL","precision-@-25-μl":"4 % CV","pipetting-increments---384-well-pipettor":"0,5 μl","range---1536-well-pipettor":"0,5 à 3 μL","precision-@-3-μl":"6 % CV","precision-@-1-μl":"10 % CV","pipetting-increments---1536-well-pipettor":"0,1 μl","96-pipettor-head---quadrant-transfer":"plaque à 384 puits","384-pipettor-head---quadrant-transfer":"plaque à 1536 puits"}],"columns":["key","name","path","identifier","simultaneous-transfer","range-96-pipettor-head","precision-@75-μl","pipetting-increments-96-pipettor-head","range---384-well-pipettor","precision-@-25-μl","pipetting-increments---384-well-pipettor","range---1536-well-pipettor","precision-@-3-μl","precision-@-1-μl","pipetting-increments---1536-well-pipettor","96-pipettor-head---quadrant-transfer","384-pipettor-head---quadrant-transfer"]},"emissionOptics-1":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","camera-type":"Type d'appareil photographique","detection":"Détection","lower-detection-limit-fluorescence":"Limite de détection inférieure (Fluorescence)","lower-detection-limit-luminescence":"Limite de détection inférieure (Luminescence)","data-acquisition-rate-fluorescence":"Vitesse d’acquisition des données (Fluorescence)","data-acquisition-rate-luminescence":"Vitesse d’acquisition des données (Luminescence)"},{"key":"value1","name":"Optiques d’émission - 1","path":"\/products\/flipr-penta-high-throughput-cellular-screening-system","identifier":"FLIPR Penta High-Throughput Cellular Screening System","camera-type":"HS-EMCCD","detection":"Luminescence et fluorescence","lower-detection-limit-fluorescence":"6,25 e-10 M FITC","lower-detection-limit-luminescence":"4 nM ATP (essai Promega Cell Titer Glow)","data-acquisition-rate-fluorescence":"Jusqu’à 100 Hz","data-acquisition-rate-luminescence":"Jusqu’à 2 Hz (selon la luminosité)"}],"columns":["key","name","path","identifier","camera-type","detection","lower-detection-limit-fluorescence","lower-detection-limit-luminescence","data-acquisition-rate-fluorescence","data-acquisition-rate-luminescence"]},"throughput":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","temperature-control":"Contrôle de la température","throughput":"Débit","96-well":"à 96 puits","384-well":"à 384 puits","1536-well":"à 1536 puits","bar-code-manual-mode-1":"Mode manuel à code barres 1","bar-code-manual-mode-2":"Mode manuel à code barres 2"},{"key":"value1","name":"Débit","path":"\/products\/flipr-penta-high-throughput-cellular-screening-system","identifier":"FLIPR Penta High-Throughput Cellular Screening System","temperature-control":"Température ambiante +5 °C à 40 °C","throughput":"20 microplaques\/heure (durée de lecture de 2 minutes)","96-well":"1 920 points de données\/heure","384-well":"7 680 points de données\/heure","1536-well":"30 720 points de données\/heure","bar-code-manual-mode-1":"Saisie par clavier","bar-code-manual-mode-2":"Côté court ou long"}],"columns":["key","name","path","identifier","temperature-control","throughput","96-well","384-well","1536-well","bar-code-manual-mode-1","bar-code-manual-mode-2"]},"product":{"total":1,"offset":0,"limit":1,"data":[{"path":"\/products\/flipr-penta-high-throughput-cellular-screening-system","title":"Système de criblage cellulaire à haut débit FLIPR Penta","identifier":"FLIPR Penta High-Throughput Cellular Screening System","categories":"general,throughput,excitationOptics,emissionOptics-1,emissionOptics-2,emissionFilters,fluidics","thumbnail":".\/media_17586e247f12bfcb9b14c6260e01bad8330d39396.png?width=750&format=png&optimize=medium"}],"columns":["path","title","identifier","categories","thumbnail"]},":version":3,":names":["excitationOptics","general","emissionFilters","emissionOptics-2","fluidics","emissionOptics-1","throughput","product"],":type":"multi-sheet"}