{"product":{"total":1,"offset":0,"limit":1,"data":[{"path":"\/products\/microplate-readers\/multi-mode-readers\/spectramax-mini-reader","identifier":"SpectraMax Mini Multi-Mode Microplate Reader","title":"Lecteur de microplaques multimode SpectraMax Mini","categories":"general,absorbanceRange,fluorescencePerf,luminescencePerf,generalPerf,standardFilterCubes,optionalFilterCubes","description":"Lecteur de microplaques multimode à prix abordable avec logiciel de pointe pour l’analyse des données","thumbnail":"\/products\/specifications\/thumbnails\/spectramax-mini.png"}],"columns":["path","identifier","title","categories","description","thumbnail"]},"optionalFilterCubes":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","filter-name":"Nom du filtre","fluorophoreassay":"Fluorophore\/dosage","excitation":"Excitation","dichroic":"Dichroïque","emission":"Émission"},{"key":"value1","name":"Cubes de filtrage en option","path":"\/products\/microplate-readers\/multi-mode-readers\/spectramax-mini-reader","identifier":"SpectraMax Mini Multi-Mode Microplate Reader","filter-name":"FL-360, FL-565, FL-635, FL-680, FL-810","fluorophoreassay":"Tryptophane, dosage des protéines Nano Orange\/Quant IT, Alexa Fluor 594, Texas Red, Alexa Fluor 647\/cy5, Alexa Fluor 750\/cy7","excitation":"280\/20, 465\/35, 590\/20, 625\/35, 710\/50","dichroic":"310, 508, 610, 655, 765","emission":"360\/35, 565\/30, 635\/25, 680\/20, 810\/40"}],"columns":["key","name","path","identifier","filter-name","fluorophoreassay","excitation","dichroic","emission"]},"absorbanceRange":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","wavelength-range":"Gamme de longueurs d'onde","wavelength-selection":"Sélection de longueur d'onde","wavelength-bandwidth":"Bande passante de longueur d'onde","wavelength-accuracy":"Précision de longueur d'onde","wavelength-precision-repeatability":"Précision de la longueur d’onde (répétabilité)","photometric-range":"Gamme photométrique","photometric-resolution":"Résolution photométrique","photometric-accuracy-linearity":"Exactitude photométrique, linéarité","stray-light":"Fond clair","photometric-precision-repeatability":"Précision photométrique (répétabilité)"},{"key":"value1","name":"Gamme photométrique d’absorbance","path":"\/products\/microplate-readers\/multi-mode-readers\/spectramax-mini-reader","identifier":"SpectraMax Mini Multi-Mode Microplate Reader","wavelength-range":"200 à 1000 nm","wavelength-selection":"Incréments de 1,0 nm","wavelength-bandwidth":"≤ 5 nm en largeur totale à mi-hauteur","wavelength-accuracy":"± 2 nm sur la gamme de longueurs d'onde","wavelength-precision-repeatability":"± 0,2 nm","photometric-range":"0 à 4,0 OD","photometric-resolution":"0,001 OD","photometric-accuracy-linearity":"< ±0,006 OD ±1,0 %, 0 à 3 OD","stray-light":"≤ 0,05 %  à 230 nm","photometric-precision-repeatability":"< ±0,003 OD ±1,0 %, 0 à 3 OD"}],"columns":["key","name","path","identifier","wavelength-range","wavelength-selection","wavelength-bandwidth","wavelength-accuracy","wavelength-precision-repeatability","photometric-range","photometric-resolution","photometric-accuracy-linearity","stray-light","photometric-precision-repeatability"]},"general":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","dimensions-in":"Dimensions (pouces)","dimensions-cm":"Dimensions (cm)","power-requirement":"Spécifications électriques","weight":"Poids","robotic-compatible":"Compatible automatisation","absorbance-fluorescence-and-luminescence":"Absorbance, fluorescence et luminescence","plate-types":"Type(s) de plaque"},{"key":"value1","name":"Caractéristiques générales","path":"\/products\/microplate-readers\/multi-mode-readers\/spectramax-mini-reader","identifier":"SpectraMax Mini Multi-Mode Microplate Reader","dimensions-in":"15,75 (L) x 12,60 (P) x 13,78 (H)","dimensions-cm":"40 (L) x 32 (P) x 35 (H)","power-requirement":"Alimentation électrique externe 24 VCC compatible avec 100–240 VCA entre 50 et 60 Hz, consommation maximale 160 W","weight":"≤ 40 livres (18 kg)","robotic-compatible":"Oui","absorbance-fluorescence-and-luminescence":"vrai","plate-types":"Plaques de 6 – 384 puits"}],"columns":["key","name","path","identifier","dimensions-in","dimensions-cm","power-requirement","weight","robotic-compatible","absorbance-fluorescence-and-luminescence","plate-types"]},"standardFilterCubes":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","dichroic":"Dichroïque","filter-name":"Nom du filtre","fluorophoreassay":"Fluorophore\/dosage","excitation":"Excitation","emission":"Émission"},{"key":"value1","name":"Cubes de filtrage standard","path":"\/products\/microplate-readers\/multi-mode-readers\/spectramax-mini-reader","identifier":"SpectraMax Mini Multi-Mode Microplate Reader","dichroic":"405, 508, 555","filter-name":"FL-465, FL-535, FL-595","fluorophoreassay":"Dérivé de coumarine (AMC), AF350, Fluorescéine\/FITC, bleu Alamar","excitation":"360\/35, 485\/20, 535\/25","emission":"465\/35, 535\/25, 595\/35"}],"columns":["key","name","path","identifier","dichroic","filter-name","fluorophoreassay","excitation","emission"]},"generalPerf":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","plate-formats":"Formats de plaques","light-source":"Source lumineuse","shaking":"Agitation","reading-capabilities":"Capacités de lecture","detectors":"Détecteurs","temperature-control":"Contrôle de la température","temperature-uniformity":"Uniformité de la température","temperature-accuracy":"Précision de la température","spectral-scanning":"Balayage spectral","endpoint-reading":"Lecture en point final","kinetic-reading":"Lecture cinétique","well-scanning":"Scan de puits"},{"key":"value1","name":"Performance générale","path":"\/products\/microplate-readers\/multi-mode-readers\/spectramax-mini-reader","identifier":"SpectraMax Mini Multi-Mode Microplate Reader","plate-formats":"Plaques à 6, 12, 24, 48, 96, 384 puits ANSI\/SLAS","light-source":"Deux lampes flash au xénon à haute énergie comme source de lumière","shaking":"Linéaire, orbital et double orbital","reading-capabilities":"Microplaques, cuvettes (avec adaptateur)","detectors":"Tube photomultiplicateur ultra-refroidi et photodiode silicone","temperature-control":"4 °C au-dessus de la température ambiante à 45 °C","temperature-uniformity":"± 1 °C à 37 °C","temperature-accuracy":"± 2 °C à 37 °C","spectral-scanning":"Abs","endpoint-reading":"Abs, FI, Lum","kinetic-reading":"Abs, FI, Lum","well-scanning":"Plus de 20 par 20"}],"columns":["key","name","path","identifier","plate-formats","light-source","shaking","reading-capabilities","detectors","temperature-control","temperature-uniformity","temperature-accuracy","spectral-scanning","endpoint-reading","kinetic-reading","well-scanning"]},"fluorescencePerf":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","wavelength-range":"Gamme de longueurs d'onde","dynamic-range":"Gamme dynamique","sensitivity-fluorescein":"Sensibilité (fluorescéine)"},{"key":"value1","name":"Performances d'intensité de la fluorescence","path":"\/products\/microplate-readers\/multi-mode-readers\/spectramax-mini-reader","identifier":"SpectraMax Mini Multi-Mode Microplate Reader","wavelength-range":"250 à 850 nm","dynamic-range":"&gt; 6 décades","sensitivity-fluorescein":"1 pM"}],"columns":["key","name","path","identifier","wavelength-range","dynamic-range","sensitivity-fluorescein"]},"luminescencePerf":{"total":2,"offset":0,"limit":2,"data":[{"key":"label","name":"Nom","path":"path","identifier":"Identifier","wavelength-range":"Gamme de longueurs d'onde","dynamic-range":"Gamme dynamique","sensitivity-atp":"Sensibilité (ATP)","cross-talk":"Lumière parasite"},{"key":"value1","name":"Performances de luminescence","path":"\/products\/microplate-readers\/multi-mode-readers\/spectramax-mini-reader","identifier":"SpectraMax Mini Multi-Mode Microplate Reader","wavelength-range":"300 à 650 nm","dynamic-range":"&gt; 7 décades","sensitivity-atp":"2 pM","cross-talk":"< 0,1 % (microplaque blanche à 96 demi-puits)"}],"columns":["key","name","path","identifier","wavelength-range","dynamic-range","sensitivity-atp","cross-talk"]},":version":3,":names":["product","optionalFilterCubes","absorbanceRange","general","standardFilterCubes","generalPerf","fluorescencePerf","luminescencePerf"],":type":"multi-sheet"}